diff --git a/src/device/DeviceManager.cpp b/src/device/DeviceManager.cpp
index 6828167..fd5d374 100644
--- a/src/device/DeviceManager.cpp
+++ b/src/device/DeviceManager.cpp
@@ -389,6 +389,7 @@ void DeviceManager::processScanProgress(const QString& aProgress)
break;
}
case 2:
+ case 3:
{
QVariant var;
if(mIsEmptyScan)
@@ -407,12 +408,6 @@ void DeviceManager::processScanProgress(const QString& aProgress)
TRIGGER_EVENT(InvokeOperationProgress, nullptr, (QObject *) &var);
break;
}
- case 3:
- {
- QVariant var(tr("Patient can leave.\nprogress:%1%").arg(msg));
- TRIGGER_EVENT(InvokeOperationProgress, nullptr, (QObject *) &var);
- break;
- }
case 4:
checkDataQuality();
break;
@@ -441,6 +436,7 @@ void DeviceManager::prepareFinishScan(bool isNormalFinish, const QString& aReaso
bool isCompleteNotify = JsonObject::Instance()->getCompleteNotify();
if(!isNormalFinish)
{
+ ScanProcessSequence::getInstance()->clear();
if(!mIsEmptyScan)
{
TRIGGER_EVENT(StopScanProcess, nullptr, nullptr);
diff --git a/src/translations/en_US.ts b/src/translations/en_US.ts
index 3da5bb9..2dbc2f8 100644
--- a/src/translations/en_US.ts
+++ b/src/translations/en_US.ts
@@ -7,10 +7,6 @@
HJ-USCT-01 V1.0
-
- ?
-
-
GUI Software V%1
@@ -2071,11 +2067,11 @@ Error:
TopBarWidget
- 浙江衡玖医疗科技
+ °C
- °C
+ 浙江衡玖医疗
diff --git a/src/translations/zh_CN.ts b/src/translations/zh_CN.ts
index 82c6cd7..2498064 100644
--- a/src/translations/zh_CN.ts
+++ b/src/translations/zh_CN.ts
@@ -4,85 +4,79 @@
AboutForm
-
-
+
+
HJ-USCT-01 V1.0
-
-
- ?
-
-
-
-
+
USCT Software V0.1.0
-
+
Reconstruction Software Loading...
-
-
+
+
GUI Software V%1
-
+
Operation System Information Loading...
-
+
DICOM Library Information Loading...
-
+
cJSON V1.7.16
-
+
Embedded Software %1
-
+
Reconstruction Software V1.2
-
+
FEB Information
-
+
Qt 5.12.0
-
+
Copyright © 2017-2022 Zhejiang Equilibrium Nine Medical Equipment Co., Ltd. All Rights Reserved
-
+
Copyright (c) 1994-2021, OFFIS e.V.
-
+
Copyright (c) 2009-2017 Dave Gamble
-
+
Copyright © 2017-2020 Zhejiang Equilibrium Nine Medical Equipment Co., Ltd. All Rights Reversed
@@ -477,21 +471,20 @@
DeviceManager
-
-
-
+
+
+
DMS connection error
DMS失去连接
-
+
progress:%1%
进度:%1%
-
-
+
Patient can leave.
progress:%1%
患者可以起身
@@ -505,8 +498,8 @@ progress:99%
-
-
+
+
Initialize Failed.
初始化失败
@@ -518,9 +511,9 @@ progress:99%
-
-
-
+
+
+
Error:
@@ -537,51 +530,51 @@ Error:
设备状态错误,无法开始空水扫查
-
+
Scan completed! Please prepare for the next scan.
After lying down, click the confirm buttonto start scanning on the next side.
扫查结束,请准备下一侧扫查。
请在趴好后再点击确认按钮!
-
+
Scan completed!
扫查结束
-
+
Error:
错误:
-
+
Start scan failed. Reason:time out.
扫查启动失败,原因:超时
-
+
Start scan failed. Reason:%1
扫查启动失败,原因:%1
-
+
Start CE Scan Failed.
CE扫查启动失败
-
+
Shut down failed, please push emergency button to shutdown.
关机失败,请按电源按钮进行关机。
-
+
Open drain vavle failed.
排水阀打开失败
-
-
+
+
Cleaning startup failed.
清洁启动失败
@@ -590,43 +583,43 @@ After lying down, click the confirm buttonto start scanning on the next side.扫查数据上传失败
-
+
Create empty scan data failed
空水数据新增失败
-
+
Create scan data failed
扫查数据新增失败
-
+
Recon disconnected.
重建软件已断开连接
-
-
+
+
Water injection failed.
注水启动失败
-
+
Recon error, can't start scan process
重建软件错误,无法开始检查流程
-
+
Start auto locate failed
自动化定位启动失败
-
+
The data quality is low, please restart the data scan.
扫查数据质量较低,请重新开始检查流程
-
+
Device reset failed, please contact maintenance person
设备复位失败,请联系维修人员
@@ -2433,7 +2426,7 @@ The emergency button has been pushed. Please reset it before other operations.
-
+
Account
账户
@@ -2454,7 +2447,7 @@ The emergency button has been pushed. Please reset it before other operations.
-
+
ShutDown
关机
@@ -2464,24 +2457,24 @@ The emergency button has been pushed. Please reset it before other operations.
-
+
Start Scan
开始检查流程
-
-
-
-
+
+
+
+
Waterflood
注水
-
-
-
+
+
+
Clean
清洁
@@ -2492,19 +2485,19 @@ The emergency button has been pushed. Please reset it before other operations.
-
+
Confirm Water Injection
注水确认
-
+
Waterflooding
注水中
-
+
Confirm Drainage
排水确认
@@ -2515,45 +2508,45 @@ The emergency button has been pushed. Please reset it before other operations.
-
-
+
+
Confirm cleaning
清洁确认
-
-
-
+
+
+
Cleaning
清洁中
-
+
exit failed.
退出失败
-
+
Waterflood finished.
注水完成
-
+
Please click the confirm button for cleaning after disinfection.
请消毒完成后,再点击确认按钮进行清洁
-
+
Waterflood failed.
注水失败
-
-
-
-
+
+
+
+
Drain
排水
@@ -2567,7 +2560,7 @@ The emergency button has been pushed. Please reset it before other operations.
-
+
Draining
排水中
@@ -2577,73 +2570,73 @@ The emergency button has been pushed. Please reset it before other operations.
请确认是否进行清洁消毒?
-
+
Drainage finished. Please do the disinfection in next step.
排水完成,请下一步进行清洁消毒
-
-
-
+
+
+
Error:
错误:
-
+
Drainage failed.
排水失败
-
+
Clean failed.
清洁失败
-
+
Shut down now ?
是否需要进行设备关机操作,请确认?
-
+
Shut Down
关机
-
-
-
+
+
+
Please confirm checking patient information to start the process
请确定患者信息开始流程
-
+
Data scanning, please keep the current position and don't move.
数据扫查中,请患者保持当前姿势,不要移动
-
+
Data exporting, patient can leave the holder
数据导出中,患者可以离开检查仓
-
+
Data exporting, patient can leave the holder, drainage in progress.
数据导出中,患者可以离开检查仓,自动排水中
-
+
cleanning finished.
清洁完成
-
+
Left side scan initiated, auto positioning in progress.
左侧扫查启动,自动定位中
-
+
Right side scan initiated, auto positioning in progress.
右侧扫查启动,自动定位中
@@ -3231,8 +3224,8 @@ parameters
TopBarWidget
- 浙江衡玖医疗科技
-
+ 浙江衡玖医疗
+